1. Use only LP-RP Receivers (Gray Molded Box) with the LogicPLUS-S Controllers (LP-42, LP-
128 and Uni-2 Plus). with the Logic
PLUS-S Controllers.
2. Branching and Teeing of two wire path is permitted with LogicPLUS-S, but should be well
planned and minimized with care given using only waterproof DBC-BR splice kits.
All wire connection/splices are to be made in a valve box.
3. LogicPLUS-S receivers must be directly attached to the 2 wire path; red wires to eld wires,
black wires to solenoid (See #4).
4.
A. All eld wiring Connections of LogicPLUS-S Receiver Red Wires (1 each to each of eld
wires) to eld wires must use the enclosed DBC-BR splice kits. See instructions on back.
B. All receiver to Valve Solenoid Connections must be waterproof, using “dry type” wire
connectors (Hit Products DBC series or 3M™ DBY/DBR series™) and/or soldered and then
installed in waterproof housings.
5. Controller, its Receivers or any LogicPLUS-S Field Wire
within 15 feet of any high voltage current that may cause electrical interference such as;
electrical panels, meters, pumps, equipment or controls.
6. Use with standard 24 VAC solenoids only.
7. Use different colored eld wires for each wire in each two-wire path.
8. LogicPLUS-S provides 4 separate eld outputs. , , and .
.